MUF-2000H Series Hand-held

Hand-held ultrasonic flow meter (MUF-2000H)

Item No.: 24
MUF-2000H Ultrasonic Flow meter is designed to measure the fluid velocity of liquid in a full or closed pipe. It is a hand-held type ultrasonic flow meter for non-invasive liquid measurement.
  • Datasheet_Ultrasonic flow meter_MUF-2000H SeriesDownload
INQUIRY
Description Specifications Sensor Type Combination

MUF-2000H Ultrasonic Flow meter is designed to measure the fluid velocity of liquid in a full or closed pipe. It is a measurement system which is both easy to install and use. Our microprocessor based, user friendly field programmable flow measurement technique creates no interruption of the process flow and has low installation costs.
 
  • 4-line LCD display with flow rate, totalizer & diagnostics
  • High accuracy: ±1.0%
  • Compact, lightweight design
  • Wide range of fluid velocities (0 to ± 10 m/s)
  • Long-life Ni-MH battery for up to 16 hours of continuous operation
  • Transducers include magnetic base for mounting on metal pipes without mounting belt or clamps
  • Less than 10 second response time
 
Principle Transit-time ultrasonic flowmeter
Accuracy ±1%
Display 4 Line LCD with illumination, support English and Italy
Communication Insulate RS232
Pipe
installation condition
  • Pipe material: Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed.
  • Pipe diameter: 15-6000mm
  • Straight pipe: upstream 10D, downstream 5D, 30D from the pump
Measuring medium Single liquid can transmit sound wave, turbidity is no more than 10000ppm and less bubble, flow rate is 0~±10m/s, such as
  • Water (hot water, chilled water, city water, sea water, waste water)
  • Sewage with small particle content
  • Oil (crude oil, lubricating oil, fuel oil, etc)
  • Chemicals like alcohol
  • Plant effluent
  • Beverage
Medium temp Sensor: -30~+90deg C (standard), -30~+160deg C (option)
Ambient condition Ambient temperature for converter: -20~+60deg C
Humidity: Converter 85%RH
Power supply
  • Built-in rechargeable Ni-MH batteries 1.2V
  • Operation time: 12 hours
  • With 90V-260V AC adapter
Power consumption 1.5W
Protection Converter: IP65,  Sensor: IP65(standard)/IP68(optional)