MEGACF-MB Coriolis flowmeter consists of two parallel tubes that are made to oscillate using a magnet. These oscillations are recorded by sensors fitted at the inlet and outlet of each tube. In a no-flow state, the oscillations are synchronized, i.e. in phase with each other, since there is no mass exerting any force on the tubes. On the other hand, any fluid, or gas flowing through the tubes generates Coriolis forces, causing the tubes to twist in proportion to the mass flow rate of the medium.
Looking for more information on our people,
technology and solutions?
Contact us: sales@mega-meter.com
Flow range | 1.2~1500000kg/hr |
Process connections | Flanged (ANSI, DIN, Tri-Clamp, Thread) |
Line size | 3~250mm |
Process temperature | -50~125℃(integral), -50~200℃(remote), -50~350℃(high temp), -200~125℃(low temp) |
Tube geometry | U-Tube with Micro Bend |
Accuracy | ±0.2% of reading(std), 0.5% or 0.1% (opt) |
Repeatability | ±0.075% of reading |
Frequency | 10-2000 Hz |
Engineering units (Mass): | kg, lb, ton |
Display: | Color Graphic OLED |
Engineering units (Temp.) | °C, °F |
Engineering units: (Volume) | m³, Liter, US Gallon, Imperial Gallon |
Zero stability | 0.1% full-scale |
Ambient temperature | -20~60 °C |
Zero Drift (%FS / °C) | 0.005 |
Max working pressure | 1.6MPa, 2.5MPa, 4.0MPa, 6.4MPa, 10MPa, 16MPa, 25MPa |
Measuring tube material | SS316L |
Power supply | (18~36)VDC or 85~260)VAC |
Housing material | SS304 |
Outputs | 4-20 mA, 0-10 kHz pulse, RS485 |
Communication | RS485, HART |
Density measuring range | 0.2~2.0 g/cc |
Density accuracy | 0.001 g/cc) |
Temperature accurac | up to ±1°C |
Protection | IP67 |
Explosion | standard type is explosion |